Corning Pc 351 Manual
In the past few years several incidents and near misses involving hot plates have been reported at Penn and at other research institutions. The cause of each incident was either electronic malfunction or user error. The following alert describes some of these events at Penn and provides guidance on how to avoid these incidents in your lab.
- Corning Pc 351 Manual Download
- Corning Pc 351 Manual 2016
- Corning Pc 351 Manual Pdf
- Corning Pc 351 Manual Software
New 48 Combination 36 Griddle And 2 Burner Hot Plate Stratus Smg-36-ob2 3274. Thermolyne Hp-A1915b Thermolyne Type 1900 Type 1900 Hot Plate Corning Pc-351 Hot Plate 120V Corning Pc-35 Digital Hotplate Stirrer Corning Pc-420. Includes manual.
March 31, 2011: A fire in Clinical Research Building occurred when the heating function of the hot plate was turned on instead of the stirrer, causing a fire in a fume hood.
May 12, 2012: A fire occurred in Chemistry 1958 when a hot plate was left on and ignited combustible materials in the laboratory.
July 2014: A Chemistry graduate student entered the lab in the morning and found that his fume hood was on fire. The fire originated from a hot plate that was left plugged in overnight but was reportedly not turned on or being used for any experiment at the time. The suspected cause was a malfunction of the Corning model PC-320 hot plate, which may have spontaneously heated to maximum temperature.
March 2015: A graduate student in the Chemistry Department reported that her Corning PC-420D hot plate unexpectedly heated to high temperature while the heat dial was in the ‘off’ position.
January 2016: A graduate student in the Chemistry Department reported that her Corning PC-420D hot plate unexpectedly heated to high temperature during an attended operation. The temperature was being monitored by both a thermocouple probe connected to the hot plate and an analog thermometer. The temperature of the hot plate spontaneously spiked beyond the target temperature of 80 C, causing a small fire, which was quickly extinguished.
Electronic malfunctions
OLDER EQUIPMENT
Hot plates manufactured prior to 1984 do not have temperature feedback controls and can spontaneously and rapidly heat beyond the set temperature while in the ‘ON’ position.
Models that are known to exhibit this problem include the Corning models PC-35 &PC-351 and Thermolyne SP46925.
NEWER EQUIPMENT
Some hot plates have a red light that indicates the hot plate is still on or is still hot. Turning the hot plate power to “off” does not disconnect the heater from the electrical source. Processors are running as long as the unit is plugged in. In the event of a firmware glitch, the unit can still begin to heat when the switch and light are off.
Exposure to elements such as cold, moisture, corrosive gas and vapor are known to increase the chance of processor failures, although this problem has also been observed in nearly-new equipment.
WHAT YOU CAN DO:
See Heating Reactions SOP/Fact Sheet in the Chemical Hygiene Plan for more information about safe heating of chemical reactions.
EQUIPMENT MAINTENANCE and REPAIR:
Replace hot plates manufactured prior to 1984. Cut the cord off of the equipment before discarding it.
Keep hot plates in good condition. Exposure to conditions such as cold, moisture, chemical spills, and corrosive vapor and gas are known to increase the likelihood of electronics failures. Clean all spills immediately and thoroughly. Do not use hot plates in cold rooms and do not store equipment in cabinets where corrosive chemicals are stored.
Replace damaged, malfunctioning, and unreliable equipment. Repair or replace hotplates with signs of damage such as corrosion or damaged electrical cords. Any equipment (hot plate or temperature probe) that exhibits unexpected temperature fluctuations or unreliable temperature control must be taken out of service immediately for repair or replacement.
Purchase hot plates with additional safety controls. Equipment with independent control circuits and safety set-points must be used when unattended heating operations are necessary. The RCT Basic from IKA is an example of a hot plate with these features. Educate yourself about these controls and use them whenever possible.
SAFE WORK PRACTICES to REDUCE LIKELIHOOD of INCIDENTS
- Use stir-only plates whenever heat is not required. This is especially important when stirring in containers that are not heat-resistant or mixing materials that should never be exposed to heat, such as those with the potential to ignite, explode, or release gas when heated.
- Request “stir” and “heat” labels for hot plates. To reduce the possibility of inadvertently turning on the heat instead of the stirring function, EHRS provides stickers that can be applied to hot plates knobs to clearly identify their function. Click Here (https://ehrsapps.isc-seo.upenn.edu/secure/fm/warnsign/)
- Do not store flammable and combustible materials in the fume hood or near hot plates. Chemical containers, flammable-waste containers, and combustible materials such as paper towels must not be stored on or near hot plates regardless of whether the hot plate is currently in use.
- Clamp temperature probe securely in bath or heating block. If the temperature probe is reading ambient temperature, a hotplate will continue to heat beyond desired temperature.
- Carefully monitor temperature. Do not walk away from the hot plate until the bath has reached desired temperature and stabilizes there for several minutes. When heating chemicals, monitor solution temperature separately from bath temperature.
Corning Pc 351 Manual Download
- If the hot plate must be used while unattended, make a plan for reducing the risks.
- Post an “Unattended Operation” sign describing the reaction or materials that are being heated. Include the date and emergency contact information for the person responsible for the work.
- Double check that all flammable and combustible materials have been removed from the hood.
- Use equipment with redundant safety controls such as the IKA RCT basic.
- Securely clamp condenser hoses and temperature probes.
- Do not leave the apparatus unattended until the target temperature has been reached and is sustained.
REDUCING SEVERITY in CASE of FAILURE
- Remove all flammable and combustible materials from the hood and return all chemical containers to their proper storage location immediately after dispensing.
- Unplug hot plates when not in use. Disconnecting the hotplate from power is the only way to ensure that a processor glitch will not result in spontaneous heating. Ensure your hotplates are unplugged at the end of the work day.
- Do not leave a hot plate unattended when in use. Use hot plates only when you will be in the lab to continuously monitor the process. If this is not possible, use the guidance below to reduce risk.
Further Reading on Hot Plate Electronic Malfunctions:
University of California Santa Cruz: Hot Plate [Failure] Study
University of Illinois Division of Research Safety: Warning about Malfunctioning Hot Plates
Lawrence Berkeley National laboratory: Hot Plate Switch Failure
Corning pc 351 manual keyword after analyzing the system lists the list of keywords related and the list of websites with related content, in addition you can see which keywords most interested customers on the this website
Keyword Suggestions
Corning Pc 351 Manual 2016
Most Searched Keywords
Domains Actived Recently
› Americanfashiondirect.com
› Bbs.duomiluntan.com
› Ccswrm.kku.ac.th
› Ebuddy.tv
› Fairford-leasing.com
› Juxtopolis.wiki
› Mihs.daltonpublicschools.com
› Ngoknumeqefy.mihanblog.com
› Sobhiran.com.pagesstudy.com
Websites Listing
We found at least 10 Websites Listing below when search with corning pc 351 manual on Search Engine
Corning PC-351 - In Stock, We Buy Sell Repair, Price Quote
We'll send you an email letting you know exactly when your piece of equipment will be available for viewing Item to Inspect: 71309-1 - Corning PC-351 Hot Plate Stirrer Error
DA: 17PA: 50MOZ Rank: 69
Corning pc 351 manual' Keyword Found Websites Listing ...
Corning PC-351 Biosurplus. Biosurplus.com Corning - PC-351. Inquire about availability. Contact Corporate. BioSurplus, Inc. 10805 Vista Sorrento Parkway Suite 200 San Diego, CA, 92121 Directions Telephone: 858-550-0800 Fax: 858-550-0255 Email: [email protected] null BioSurplus.com Hours: Monday - Friday 9:00am - 5:00pm, PST. Knowledge Center.
DA: 28PA: 30MOZ Rank: 58
Corning PC-351 Hot Plate Stirrer - In Stock, We Buy Sell ...
Contact Us . 888-88-SOURCE . Email Customer Service. Email this page. Share: Description The Corning PC-351 Hot Plate Stirrer has a sturdy ceramic top and independent heating and stirring controls. ... 888-88-SOURCE . Email Customer Service. Email this page. Share: Resources. Manuals, Datasheets, Drivers, Links • Link to Corning Website ...
DA: 17PA: 50MOZ Rank: 67
Corning Pc-351 Laboratory Hot Plate Stirrer PC351 for sale ...
Find many great new & used options and get the best deals for Corning Pc-351 Laboratory Hot Plate Stirrer PC351 at the best online prices at eBay! Free shipping for many products! ... 99.6% Positive feedback Contact seller. Corning Pc-351 Laboratory Hot Plate Stirrer PC351. 5 product ratings About this product. Pre-owned: lowest price. $79.99 ...
DA: 12PA: 13MOZ Rank: 25
Corning PC-351 PC351 Hot Plate Stirrer. For Sale, Price ...
Corning PC-351 PC351 Hot Plate Stirrer Used, refurbished, service, repair. Scientific Support
DA: 19PA: 50MOZ Rank: 73
Corning PC-410D Manuals
Corning PC-410D Manuals Manuals and User Guides for CORNING PC-410D. We have 3 CORNING PC-410D manuals available for free PDF download: Instruction Manual
DA: 18PA: 38MOZ Rank: 56
Contact Us Email and Location Information Corning
Corning Pc 351 Manual Pdf
Contact Corning with your questions and comments. Lets Corning work with partners to enable social features and marketing messages.
DA: 15PA: 29MOZ Rank: 44
Corning Replacement Parts - York Scientific
We stock and service Corning equipment, replacement parts and related systems - both current and discontinued products. Expedited shipping and repair services are available for your urgent requirements. Select from our inventory results below or call us at (212) 772- 6992 ext. 704 or email [email protected] for help with your Corning requirements.
Corning Pc 351 Manual Software
DA: 22PA: 17MOZ Rank: 39
Instruction Manual - 120V/100V
Corning B.V. Life Sciences Koolhovenlaan 12 1119 NE Schiphol-Rijk The Netherlands Tel: 31 (0) 20-659-60-51 Fax: 31 (0) 20-659-76-73 e-mail: [email protected] France Corning S.A. 7 bis, Avenue de Valvins - Bat. E BP 61 77211 Avon Cedex France Tel: 33 (0) 1 64 69 75 60 Fax: 33 (0) 1 64 69 75 80 A listing of authorized Corning support offices ...
DA: 28PA: 28MOZ Rank: 28
› Animal jam 1000 gem codes
› The truth lies or lays
› Corning pc 351 manual
› Rosa parks impact on civil rights movement
› Wait in batch
› Sheet of paper pixel size
Top