Ansul Inergen Clean-Agent Fire Suppression Systems. You then have a choice of setting up your cylinders to open electrically, pneumatically or manually, depending on your need. Jnergen is listed and approved by governmental, nationally and internationally recognized testing laboratories. INERGEN® is a mixture of 52% Nitrogen, 40% Argon and 8% CO2. However, in the event of a fire, when INERGEN® is discharged, it mixes with the air present in the room to create a mixture that comprises of 67.3% Nitrogen, 12.5% Oxygen, 17% Argon and 3.2% Carbon Dioxide. The Inergen ® system is a fire extinguishing system for enclosed spaces. Inergen ® is a clean agent consisting of atmospheric gases and can be applied on merchant marine and offshore structures. Inergen ® extin-guishes the fire by reducing the oxygen level in the protected space without compromising people’s health and safety. This manual is intended for use with ANSUL® R-102 Restaurant Fire Suppression Systems. Those who install, operate, recharge, or maintain these fire sup-pression systems should read this entire manual. Specific sec-tions will be of particular interest depending upon one’s responsibilities. Design, installation, recharge, and maintenance of.

  1. Software Installation Manual
  2. Inergen Installation Manual Pdf
  3. Inergen Installation Manual Instructions
  4. Inergen Installation Manual Download
  5. Installation Guide

The amount of INERGEN agent to be provided shall be the amount required to obtain a uniform (minimum) concentration as required by the ANSUL INERGEN. The Ansul INERGEN Fire Suppression System protects enclosed areas where people may be present. Safe for people, INERGEN agent is.

Author:Kigalkree Akinoktilar
Country:Madagascar
Language:English (Spanish)
Genre:Science
Published (Last):9 March 2012
Pages:311
PDF File Size:9.69 Mb
ePub File Size:3.90 Mb
ISBN:887-4-38298-941-1
Downloads:25299
Price:Free* [*Free Regsitration Required]
Uploader:Gardat

Koetter is experienced in the installation and servicing of these complex systems provided by top-rated vendors such as: Prevent the loss of costly equipment, irreplaceable data and information as well as infrgen interruption. Simply stated, the human body is stimulated by the carbon dioxide to breathe more deeply and rapidly to compensate for the lower oxygen content of the atmosphere.

In addition to our corporate office located in Dallas Texas, KFPI has branch offices in Taiwan, Japan and China, as well as worldwide strategic partners to consistently support your global needs. It is listed and approved by governmental, nationally and internationally recognized testing laboratories.

An early warning fire detector senses minimal, invisible smoke. Ansul Inergen clean agent fire suppression systems protect enclosed areas where there is a need for quick reaction to a fire, where people may be present, where fire may strike day or night, and where damage from conventional agents cannot be tolerated.

In conjunction with manual pull stations, the system provides automatic detection, day and night.

INERGEN Fire Suppression System by Ansul

Available in four sizes, you can choose to install your cylinders either vertically or horizontally, allowing for a design that requires the fewest number of cylinders ahsul the ajsul cost. Special Fire Hazard Suppression Systems. The system is installed and serviced by authorized distributors that are trained by the manufacturer. Accessories are used ansuo provide alarms, ventilation control, door closures, or other auxiliary shutdown or functions. Because it is not a synthetic chemical, it has not been banned or restricted for use by any country.

With clean agent fire suppression, there is no agent to clean up and you are back in business faster. Fires are suppressed quickly with no residue to clean up. A system installation and maintenance manual is available containing information on system components and procedures concerning design, operation, inspection, maintenance, and recharge. After the required time delay, it energizes the cylinder electric actuator.

Manual

Ansul Inergen Clean-Agent Fire Suppression Systems

The system can be actuated by detection and control equipment for automatic system operation along with providing local and inrgen manual operation as needed. Count on Koetter Ansjl to design, install, service, inspect and maintain your fire protection systems to ensure you are always prepared. Support 24×7 You Can Count On! The cleanroom environment is unique in today’s manufacturing and the requirements for cleanli- ness, performance, and business continuity are critical to the success of any semiconductor operation.

The detection portion of the fire suppression system allows for automatic detection by means of specifically rated mechanical fusible links or electric thermal detectors. Our factory trained design experts produce engineered drawings using the latest versions of AutoCAD detailing the expected performance of your Inergen system.

Notifier, Protectowire, Cooper-Wheelock and others, that work in conjunction with your fire detection systems and equipment. Fire Suppression non-portable, specialty applications – Koetter is an authorized distributor of Amerex, Ansul, Firetrace, Pyro-Chem and other fire suppression products and systems. Best in Class Suppliers. Koetter Fire represents only the most recognized manufactures of highly specialized Fire Detection equipment like Fire Sentry, Protectowire and Vesda.

Software Installation Manual

Koetter Fire’s Service Department offers hour emergency service and routine service to keep your Inergen fire system operational at all times. Additional accessories are available for shutting down electrical power to equipment and shutting down the flow of gas lines.

Protectowire Pyrochem Stat-X Vesda.

Inergen Installation Manual Pdf

Unlike halocarbon chemical alternatives, which can create dangerous levels of hydrogen fluoride when in the presence of fire, INERGEN is entirely nontoxic, producing no corrosive decomposition products whatsoever. INERGEN agent is composed of three naturally occurring gases found in the air we breathe – nitrogen, argon and a small amount of carbon dioxide, which improves human safety.

Once discharged, it simply returns to the atmosphere in its natural state. Koetter specializes in design and installation of CO2 fire suppression systems for the semiconductor industry asnul are recognized by Ansul as one of inerhen 10 companies in the U. Whether you need heat detectors, smoke detectors, ionization or other sophisticated infrared detectors, rely on Koetter Fire for your fire detection plan and solution. The Amerex Zone Defense Restaurant Fire Suppression System is a pre-engineered, wet chemical, stored-pressure type with a fixed nozzle agent distribution network that is fully self-contained and does not require outside water or power supply.

We specialize in design and installation of CO2 fire suppression systems for the semiconductor industry. The Ansul Inergen Fire Suppression System is a pre-engineered, stored pressure with a fixed nozzle distribution network.

As a full-service contractor, our services include a full line of portable and fixed system fire extinguishers, engineered suppression systems, fire alarm systems, sprinkler systems, emergency mass notification systems and detection and control. Fire Sentry Firetrace Kidde Notifier.

Inergen Installation Manual Instructions

INERGEN Fire Suppression System by Ansul – BFPE International

The Stat-X fire suppressant is a patented potassium-based aerosol that suppresses fire by chemically interfering with the free radicals of flame. Koetter Fire is an authorized distributor of fire detection and suppression systems manu- factured by the biggest and best industry brand names.

Inergen Installation Manual Download

In minutes, fire and the attempts to put it out can destroy the equipment that keeps your operation in action.

Installation Guide

Related Posts